PASS W/ CONDITIONS
Risk 1 (High)
DICOLA SEAFOOD Gets Conditional Pass on Health Inspection - Chicago Restaurant
February 6, 2013
Complaint
License #15153
5
Total Violations
1
Critical
1
Major
3
Minor
Violations Cited by Chicago Health Inspector
5
Violation #8
CRITICAL
Violation Details
SANITIZING RINSE FOR EQUIPMENT AND UTENSILS: CLEAN, PROPER TEMPERATURE, CONCENTRATION, EXPOSURE TIME - Comments: DISH MACHINE NOT PROPERLY SANITIZING TO 180*F AT THIS TIME, BOTH THERMOMETERS READING 151.7*F. MACHINE TAGGED INSTRUCTED NOT TO USE CALL REPAIR MAN, AND USE THE 3 COMPARTMENT SINKS TO WASH RINSE AND SANITIZE POTS AND TRAYS WITH 100 PPM CHLORINE SANITIZER. INSTRUCTED TO FAX LETTER WHEN REPAIRED TO CDPH ATTN SUPERVISOR BHATTAL 1-321-746-4240.
Why This Matters
Improper sanitization fails to kill pathogens, allowing contaminated equipment to spread illness throughout facility.
Food Code Requirement
Sanitizing solutions and rinse water must meet specific requirements for effectiveness.
Specific Requirements
Chemical sanitizers: Chlorine 50-100 ppm, Quaternary ammonium 200-400 ppm, Iodine 12.5-25 ppm; Hot water: 171°F for 30 seconds or 180°F at dish surface; Test strips required; Proper contact time.
CDPH Food Code: Section 4-501.114, 4-702.11
Violation #33
MAJOR
Violation Details
FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS - Comments: CLEAN AND SANITIZE REAR PREP TABLES, CUTTING BOARDS.
Why This Matters
Dirty equipment harbors bacteria and attracts pests.
Food Code Requirement
All equipment and utensils must be clean and properly maintained.
Specific Requirements
Equipment clean to sight and touch; Free of food debris and grease; Maintained in good repair; Stored properly when clean.
CDPH Food Code: Section 4-601.11
Violation #34
MINOR
Violation Details
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED - Comments: CLEAN FLOOR BEHIND FRYERS.CLEAN FLOOR DRAINS IN PREP AREA.
Why This Matters
Damaged floors harbor bacteria and create safety hazards.
Food Code Requirement
Floors must be smooth, cleanable, and maintained.
Specific Requirements
Smooth, non-porous in food areas; Properly sloped to drains; Coving at wall junctures; Kept clean; Good repair.
CDPH Food Code: Section 6-201.13
Violation #35
MINOR
Violation Details
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS - Comments: REPAIR CEILING IN LADIES RESTROOM, AND CLEAN CEILING VENT COVER IN RESTROOM.
Why This Matters
Damaged surfaces cannot be properly cleaned and may harbor pests.
Food Code Requirement
Walls and ceilings must be smooth, cleanable, and in good repair.
Specific Requirements
Smooth, washable surfaces in food areas; Light colored; No holes or cracks; Clean and maintained.
CDPH Food Code: Section 6-201.11
Violation #35
MINOR
Violation Details
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS - Comments: REPAIR CEILING IN LADIES RESTROOM, AND CLEAN CEILING VENT COVER IN RESTROOM.
Why This Matters
Damaged surfaces cannot be properly cleaned and may harbor pests.
Food Code Requirement
Walls and ceilings must be smooth, cleanable, and in good repair.
Specific Requirements
Smooth, washable surfaces in food areas; Light colored; No holes or cracks; Clean and maintained.
CDPH Food Code: Section 6-201.11
Health Department Information
Department
Chicago Department of Public Health (CDPH)
Division
Food Protection Program
Report Issues
Call 311 or File Online
More Information
CDPH Food Protection