⚠️ Recent Failed Inspections ⚠️
FAIL Risk 1 (High)

COZY CORNER RESTAURANT Fails Health Inspection - Chicago Restaurant

COZY CORNER RESTAURANT 6349-6353 N CLARK ST, CHICAGO 60660 Restaurant
May 1, 2023 Complaint License #2442541
8
Total Violations
6
Critical
1
Major
1
Minor

Violations Cited by Chicago Health Inspector

8
Violation #6
CRITICAL
PROPER EATING, TASTING, DRINKING, OR TOBACCO USE - Comments: NOTED EMPLOYEES DRINKING AND PREPARING FOOD AT THE KITCHEN PREP AREA. INSTRUCTED MANAGEMENT TO PROVIDE A DESIGNATED AREA FOR EMPLOYEES TO DRINK AND EAT AND NOT AT THE PREP AREAS.
Hands are #1 vehicle for pathogen transfer. Bare hand contact with ready-to-eat foods causes majority of foodborne outbreaks.
Proper handwashing and no bare hand contact with ready-to-eat foods.
Wash hands for 20 seconds with soap and warm water; Use utensils, deli tissue, or gloves for ready-to-eat foods; Wash hands after restroom, handling raw foods, touching face/hair, and between tasks.
Violation #10
CRITICAL
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: NOTED NO PAPER TOWELS AT THE HAND WASHING SINK OF THE FRONT PREP AREA. INSTRUCTED TO HAVE SOAP AND PAPER TOWELS AT ALL HAND WASHING SINKS. PRIORITY FOUNDATION VIOLATION #7-38-030(C). CITATION ISSUED.
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
Violation #10
CRITICAL
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: NOTED NO HAND WASHING SIGNS AT THE HAND WASHING SINKS. INSTRUCTED TO HAVE HAND WASHING SINGNS AT ALL AHND WASH SINKS.
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
Violation #22
CRITICAL
PROPER COLD HOLDING TEMPERATURES - Comments: NOTED INTERNAL TEMPERATURE OF THE FOLLOWING TCS FOOD ITEMS INSIDE SERVICE COOLERS TO BE IMPROPER:-EGGS 56.8F, CREAM OF CHICKEN 50.5F.MANAGER IMMEDIATELY AND VOLUNTARILY DISPOSED OF 15 LBS OF PRODUCTS WORTH $30.00 THROUGH DENATURING PROCESS. PRIORITY VIOLATION #7-38-005. CITATION ISSUED.
Temperatures below 135°F allow bacteria to multiply, especially spore-formers that survive cooking.
Hot foods must be held at 135°F or above.
Maintain 135°F or above; Check temperatures regularly; Proper hot holding equipment; Cannot reheat in hot holding units.
Violation #47
MINOR
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: NOTED TORN RUBBER GASKET INSIDE DOOR OF THE WALK IN COOLER AT THE KITCHEN PREP. INSTRUCTED TO DETAIL REPAIR AND MAINTAIN AND/OR REPLACE.
Poor design creates areas that harbor bacteria.
All surfaces must be designed to be easily cleanable.
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
Violation #48
CRITICAL
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: NOTED NO SANITIZER TEST STRIP KIT ON SITE AT THE TIME OF INSPECTION. INSTRUCTED TO HAVE A TEST STRIP KIT ON SITE AT ALL TIMES TO PROPERLY MONITOR THE STRENGTH OF THE SANITIZER PF. PRIORITY FOUNDATION. VIOLATION#7-38-005. CITATION ISSUED.
Cannot verify sanitization without test strips, risking contaminated equipment.
Warewashing facilities must be properly equipped and supplied.
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.
Violation #48
CRITICAL
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: NOTED PREMISE USING A HIGH TEMPERATURE DISH WASHER WITH GAUGE READING 188F; HOWEVER NOTED NO TEMPERATURE TEST STRIPSOR IRREVERSIBLE REGISTERING TEMPERATURE INDICATOR. INSTRUCTED TO PROVIDE AND IRREVERSIBLE REGISTERING TEMPERATURE INDICATOR, STRIPS/STICKERS. PRIORITY FOUNDATION VIOLATION#7-38-005. CITATION ISSUED TODAY. CONSOLIDATED WITH ABOVE VIOLATION.
Cannot verify sanitization without test strips, risking contaminated equipment.
Warewashing facilities must be properly equipped and supplied.
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.
Violation #48
CRITICAL
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: NOTED PREMISE USING A HIGH TEMPERATURE DISH WASHER WITH GAUGE READING 188F; HOWEVER NOTED NO TEMPERATURE TEST STRIPSOR IRREVERSIBLE REGISTERING TEMPERATURE INDICATOR. INSTRUCTED TO PROVIDE AND IRREVERSIBLE REGISTERING TEMPERATURE INDICATOR, STRIPS/STICKERS. PRIORITY FOUNDATION VIOLATION#7-38-005. CITATION ISSUED TODAY. CONSOLIDATED WITH ABOVE VIOLATION.
Cannot verify sanitization without test strips, risking contaminated equipment.
Warewashing facilities must be properly equipped and supplied.
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection
Data sourced from Chicago Open Data Portal - Chicago Department of Public Health inspections