FAIL Risk 1 (High)

Costco Wholesale # 380 Fails Health Inspection - Chicago Grocery store

Costco Wholesale # 380 (AKA: Costco Wholesale) 2746 N CLYBOURN AVE, CHICAGO 60614 Grocery Store
June 22, 2020 Complaint License #1044650
7
Total Violations
5
Critical
1
Major
1
Minor
1
Corrected On Site

Violations Cited by Chicago Health Inspector

7
Violation #3
CRITICAL
MANAGEMENT, FOOD EMPLOYEE AND CONDITIONAL EMPLOYEE; KNOWLEDGE, RESPONSIBILITIES AND REPORTING - Comments: FOUND NO EMPLOYEE HEALTH POLICY/TRAINING ON SITE. INSTRUCTED FACILITY TO ESTABLISH AN APPROPRIATE EMPLOYEE HEALTH POLICY/TRAINING SYSTEM AND MAINTAIN WITH VERIFIABLE DOCUMENTS ON SITE. PRIORITY FOUNDATION VIOLATION 7-38-010.
Ill food workers cause 70% of foodborne outbreaks. Proper reporting prevents transmission of Norovirus, Hepatitis A, Salmonella, and other serious diseases.
All food employees must understand and follow health reporting requirements and food safety responsibilities.
Employees must: Report illness symptoms and exposures; Be excluded/restricted when ill; Understand their role in preventing foodborne illness; Follow proper hygiene practices; Have signed health policy on file.
Violation #5
CRITICAL
PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS - Comments: FOUND PROCEDURE/PLAN ON SITE HOWEVER KIT NOT COMPLETE MISSING SOLUTION TO CONTROL NOROVIRUS FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS, ALSO MISSING MOP ETC. INSTRUCTED FACILITY TO MAINTAIN ANY APPROPRIATE SUPPLIES ON SITE. PRIORITY FOUNDATION VIOLATION 7-38-005.
Vomit and diarrhea contain millions of viral particles. One incident can contaminate entire facility and cause outbreak affecting dozens.
Written procedures required for cleaning bodily fluid events to prevent disease transmission.
Written procedure must address: Isolating contaminated area; Removing and discarding affected food; Using proper PPE; Cleaning and sanitizing with appropriate concentration; Proper disposal of contaminated materials.
Violation #10
CRITICAL
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: NO HOT WATER PROVIDED AT HANDWASHING SINK AT COURT FOOD PREP/PIZZA AREA . PRESENTLY AT TEMP OF 71.4F TO 72.6F. AT 12:25PM WATER TEMPERATURE AT SAID SINK WAS 67F TO 68F. AT 12:35 ONE HANDWASHING SINK HOT WATER PROVIDED 107F,THE OTHER HANDWASHING SINK UNABLE TO PROVIDED HOT WATER IT REACHED 91F BUT INSTANTLY WENT DOWN TO 81F AND BELOW. INSTRUCTED TEMPORARILY TO USE ONE HANDWASHING SINK AT PREP PIZZA AREA. MUST PROVIDE HOT WATER WITH A MINIMUM TEMPERATURE OF 100F AT SAID HANDWASHING SINK. FOR SHORT PERIOD OF TIME( 20 MINUTES TO 1/2 HOURS FOOD PREPARATION WAS STOPPED UNTIL HOT WATER PROVIDE). PRIORITY VIOLATION 7-38-030(C)
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
Violation #48
CORRECTED CRITICAL
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: WRONG SANITIZER CHEMICAL TEST STRIP PROVIDED AT THREE COMPARTMENT SINK AT DELI DEPARTMENT. UPON MY REQUEST MANAGER PROVIDED THE CORRECTED QUATERNARY CHEMICAL TEST STRIP. PRIORITY FOUNDATION VIOLATION 7-38-005
Cannot verify sanitization without test strips, risking contaminated equipment.
Warewashing facilities must be properly equipped and supplied.
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.
This violation was corrected during the inspection.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: LEAKING PIPE UNDER THREE COMPARTMENT SINK AT MEAT DEPARTMENT, ALSO FLOOR DRAIN AT SOUTH EAST CORNER BY THE THREE COMPARTMENT SINK SLOWLY DRAINING. STANDING RUSTY WATER BY THE TWO DOOR REACH-IN COOLER.INSTRUCTED TO REPAIR ISSUE
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
Violation #53
MAJOR
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED - Comments: NO LID PROVIDED AT RECEPTACLE INSIDE THE STAFF WASHROOM AT REAR STORAGE AREA
Inadequate facilities lead to poor hygiene and contamination.
Toilet rooms must be properly equipped and maintained.
Self-closing doors; Toilet paper; Covered waste receptacles; Handwashing supplies; Cleaned regularly; Proper ventilation.
Violation #53
MAJOR
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED - Comments: NO LID PROVIDED AT RECEPTACLE INSIDE THE STAFF WASHROOM AT REAR STORAGE AREA
Inadequate facilities lead to poor hygiene and contamination.
Toilet rooms must be properly equipped and maintained.
Self-closing doors; Toilet paper; Covered waste receptacles; Handwashing supplies; Cleaned regularly; Proper ventilation.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection
Data sourced from Chicago Open Data Portal - Chicago Department of Public Health inspections