⚠️ Recent Failed Inspections ⚠️
FAIL Risk 1 (High)

THE ATRIUM HLTH CARE CTRS, INC Fails Health Inspection - Chicago Long term care

THE ATRIUM HLTH CARE CTRS, INC (AKA: THE ATRIUM) 1425 W ESTES AVE, CHICAGO 60626 Long Term Care
March 18, 2025 Canvass License #2204272
8
Total Violations
5
Critical
3
Minor
1
Corrected On Site

Violations Cited by Chicago Health Inspector

8
Violation #8
CORRECTED CRITICAL
HANDS CLEAN & PROPERLY WASHED - Comments: OBSERVED EMPLOYEE IN THE DISHROOM HANDLING DIRTY DISHES/GLASSES AND PUT THEM THRU THE LOW TEMP DISH MACHINE AND WITHOUT PROPER HAND WASHING HANDLED AND STORED CLEAN DISHES.ALSO OBSERVED THE COOK NOT WASHING HANDS EVERY POSSIBLE CONTAMINATION AS HE WAS PREPARING FOOD. MUST WASH HANDS EVERY POSSIBLE CONTAMINATION.MANAGER CORRECTED THE ISSUE PRIORITY CITATION:7-38-010,CITATION ISSUED
Improper sanitization fails to kill pathogens, allowing contaminated equipment to spread illness throughout facility.
Sanitizing solutions and rinse water must meet specific requirements for effectiveness.
Chemical sanitizers: Chlorine 50-100 ppm, Quaternary ammonium 200-400 ppm, Iodine 12.5-25 ppm; Hot water: 171°F for 30 seconds or 180°F at dish surface; Test strips required; Proper contact time.
This violation was corrected during the inspection.
Violation #16
CRITICAL
FOOD-CONTACT SURFACES: CLEANED & SANITIZED - Comments: OBSERVED ICE/FOOD NOT PROTECTED. INTERIOR OF THE ICE MACHINES UPPER WATER RESERVOIR, ICE BIN, AND ALL ICE CONTACT SIDES AND INTERIOR OF THE MACHINE WITH BLACK AND PINK SLIME SUBSTANCE DRIPPING DOWN INTO THE ICE AND TOUCHING THE ICE. INSTRUCTED TO CLEAN AND SANITIZE THE INTERIOR OF THE ICE MACHINE THROUGHOUT. PRIORITY FOUNDATION VIOLATION 7-38-005 CITATION ISSUED.
Dirty equipment harbors and spreads pathogens, causing cross-contamination and illness.
All food contact surfaces must be properly cleaned and sanitized.
Wash, rinse, sanitize after each use; Clean between different raw foods; Every 4 hours for continuous use; When contaminated; Proper procedures and chemicals.
Violation #16
CRITICAL
FOOD-CONTACT SURFACES: CLEANED & SANITIZED - Comments: OBSERVED NO CHLORINE DETECTED AT THE FINAL RINSE OF THE LOW TEMPERATURE DISH MACHINE,OPPM.UNIT IN USE. TAGGED UNIT "HELD FOR INSPECTION" DO NOT USE. USE THREE COMPARTMENT SINK AND THE OTHER LOW TEMP DISH MACHINE. MANAGEMENT INSTRUCTED TO REPAIR AND MAINTAIN THE MACHINE WITH A FINAL RINSE OF 100PPM CHLORINE. PRIORITY VIOLATION 7-38-025. CITATION ISSUED.
Dirty equipment harbors and spreads pathogens, causing cross-contamination and illness.
All food contact surfaces must be properly cleaned and sanitized.
Wash, rinse, sanitize after each use; Clean between different raw foods; Every 4 hours for continuous use; When contaminated; Proper procedures and chemicals.
Violation #22
CRITICAL
PROPER COLD HOLDING TEMPERATURES - Comments: WE OBSERVED COOKED PULLED TURKEY STORED INSIDE THE TWO DOOR REACH-IN COOLER IN THE KITCHEN AT IMPROPER TEMPERATURE: 58.6F TO 60.5F FOOD DISCARDED AND DENATURED.POUNDS 40F , VALUE 267. PRIORITY VIOLATION: 7-38-005,CITATION ISSUED.
Temperatures below 135°F allow bacteria to multiply, especially spore-formers that survive cooking.
Hot foods must be held at 135°F or above.
Maintain 135°F or above; Check temperatures regularly; Proper hot holding equipment; Cannot reheat in hot holding units.
Violation #47
MINOR
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: MUST NOT USE MILK CRATES AS A MEANS OF ELEVATION FOR STORED ITEMS.
Poor design creates areas that harbor bacteria.
All surfaces must be designed to be easily cleanable.
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
Violation #49
MINOR
NON-FOOD/FOOD CONTACT SURFACES CLEAN - Comments: EXCESS DRY GRIMES UNDER THE LOW TEMP DISHMACHINE DRIAN BOARD. MUST CLEAN AND MAINTAIN
Accumulated soil attracts pests and harbors bacteria.
All surfaces must be kept clean.
Clean equipment interiors and exteriors; Walls, ceilings, floors clean; Remove grease and debris; Clean as often as necessary.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: REPAIR LEAKING BOOSTER UNDER THE TAGGED LOW TEMP DISHMACHINE
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: REPAIR LEAKING BOOSTER UNDER THE TAGGED LOW TEMP DISHMACHINE
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection