PASS
Risk 1 (High)
TAQUERIA LOS COMPADRES Passes Health Inspection - Chicago Restaurant
May 19, 2025
Canvass
License #2886568
4
Total Violations
1
Critical
3
Minor
Violations Cited by Chicago Health Inspector
4
Violation #47
MINOR
Violation Details
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: INSRUCTED TO PROVIDE SMOOTH AND EASILY CLEANABLE SPLASHGUARD ON HANDSINK LOCATED NEXT TO ICE MACHINE AND DRYING RACK WITH CLEAN KITCHEN USTENSILS. MUST MAINTAIN IN ORDER TO PREVENT POSSIBLE CONTAMINATION.
Why This Matters
Poor design creates areas that harbor bacteria.
Food Code Requirement
All surfaces must be designed to be easily cleanable.
Specific Requirements
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
CDPH Food Code: Section 4-101.11
Violation #49
MINOR
Violation Details
NON-FOOD/FOOD CONTACT SURFACES CLEAN - Comments: OBSERVED UPRIGHT COOLER AS WELL AS 2 DOOR COOLING UNIT WITH COLD HOLD ATTACHED LOCATED IN PREP AREA IN NEED OF CLEANING. INSTRUCTED TO CLEAN AND REMOVE ALL DRIED FOOD DEBRIS ON INTERIOR SURFACES OF EQUIPMENT.
Why This Matters
Accumulated soil attracts pests and harbors bacteria.
Food Code Requirement
All surfaces must be kept clean.
Specific Requirements
Clean equipment interiors and exteriors; Walls, ceilings, floors clean; Remove grease and debris; Clean as often as necessary.
CDPH Food Code: Section 4-601.11, 4-602.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED HANDWASHING SINK LOCATED IN FRONT PREP AREA SLOW DRAINING. INSTRUCTED TO REPAIR AND MAINTAIN IN GOOD CONDITION.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED HANDWASHING SINK LOCATED IN FRONT PREP AREA SLOW DRAINING. INSTRUCTED TO REPAIR AND MAINTAIN IN GOOD CONDITION.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Health Department Information
Department
Chicago Department of Public Health (CDPH)
Division
Food Protection Program
Report Issues
Call 311 or File Online
More Information
CDPH Food Protection