FAIL
Risk 1 (High)
T JOELS FAMILY RESTAURANT Fails Health Inspection - Chicago Restaurant
February 21, 2012
Canvass
License #1332161
7
Total Violations
1
Critical
3
Major
3
Minor
Violations Cited by Chicago Health Inspector
7
Violation #24
MAJOR
Violation Details
DISH WASHING FACILITIES: PROPERLY DESIGNED, CONSTRUCTED, MAINTAINED, INSTALLED, LOCATED AND OPERATED - Comments: All dishwashing machines must be of a type that complies with all requirements of the plumbing section of the Municipal Code of Chicago and Rules and Regulation of the Board of Health. FOUND THE 3 COMP SINK NOT MAINTAINED I.E.GREASE TRAP BOX BENEATH SAID SINK IS NOT CLEAN,SLOW DRAINING.MUST REPAIR AS REQUIRED.SERIOUS VIOLATION (7-38-030).
Why This Matters
Inadequate facilities prevent proper cleaning and sanitization of equipment.
Food Code Requirement
Warewashing facilities must meet design and operational requirements.
Specific Requirements
3-compartment sink with drainboards; Mechanical dishwasher with proper temperatures; Test strips; Thermometers; Adequate size.
CDPH Food Code: Section 4-301.11, 4-501.14
Violation #33
MAJOR
Violation Details
FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS - Comments: All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily. THE FOLLOWING REQUIRES A DETAIL CLEANING SHELVINGS AT COOKLINE,INTERIOR/EXTERIOR OF COOLERS,BOTTOMS OF FOOD PREP TABLES.
Why This Matters
Dirty equipment harbors bacteria and attracts pests.
Food Code Requirement
All equipment and utensils must be clean and properly maintained.
Specific Requirements
Equipment clean to sight and touch; Free of food debris and grease; Maintained in good repair; Stored properly when clean.
CDPH Food Code: Section 4-601.11
Violation #34
MINOR
Violation Details
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED - Comments: The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair.FLOORS BENEATH THE COOKING EQUIPMENTS,FLOORS IN BASEMENT DRY STORAGE ARE DIRTY,CLEAN FLOORS IN DETAIL.
Why This Matters
Damaged floors harbor bacteria and create safety hazards.
Food Code Requirement
Floors must be smooth, cleanable, and maintained.
Specific Requirements
Smooth, non-porous in food areas; Properly sloped to drains; Coving at wall junctures; Kept clean; Good repair.
CDPH Food Code: Section 6-201.13
Violation #35
MINOR
Violation Details
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS - Comments: The walls and ceilings shall be in good repair and easily cleaned. WALLS IN BASEMENT DRY STORAGE AREAS,ABOVE 3 COMP SINK AREAS MUST BE SMOOTH,EASILY CLEANABLE SURFACE.
Why This Matters
Damaged surfaces cannot be properly cleaned and may harbor pests.
Food Code Requirement
Walls and ceilings must be smooth, cleanable, and in good repair.
Specific Requirements
Smooth, washable surfaces in food areas; Light colored; No holes or cracks; Clean and maintained.
CDPH Food Code: Section 6-201.11
Violation #36
MINOR
Violation Details
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: Shielding to protect against broken glass falling into food shall be provided for all artificial lighting sources in preparation, service, and display facilities.LIGHT BULBS OVER CHEST FREEZER IN THE DRY STORAGE AREA,REAR DISHWASHING AREA MUST BE SHIELDED WITH END CAPS.
Why This Matters
Inadequate lighting prevents detection of contamination and pests.
Food Code Requirement
Adequate protected lighting required in all areas.
Specific Requirements
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.
CDPH Food Code: Section 6-303.11
Violation #38
CRITICAL
Violation Details
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED - Comments: Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health. MUST INSTALL MISSING HANDLE/KNOB FOR HOT WATER AT THE MOP SINK AND VENTILATION COVERS IN TOILET ROOMS REQUIRE CLEANING.
Why This Matters
Pests spread numerous diseases through contamination.
Food Code Requirement
No pests or animals allowed in facility.
Specific Requirements
No evidence of pests; No live animals except service animals; Effective pest control program.
CDPH Food Code: Section 6-501.111
Violation #38
CRITICAL
Violation Details
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED - Comments: Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health. MUST INSTALL MISSING HANDLE/KNOB FOR HOT WATER AT THE MOP SINK AND VENTILATION COVERS IN TOILET ROOMS REQUIRE CLEANING.
Why This Matters
Pests spread numerous diseases through contamination.
Food Code Requirement
No pests or animals allowed in facility.
Specific Requirements
No evidence of pests; No live animals except service animals; Effective pest control program.
CDPH Food Code: Section 6-501.111
Health Department Information
Department
Chicago Department of Public Health (CDPH)
Division
Food Protection Program
Report Issues
Call 311 or File Online
More Information
CDPH Food Protection