FAIL Risk 2 (Medium)

STARBUCKS COFFEE #2929 Fails Health Inspection - Chicago Restaurant

STARBUCKS COFFEE #2929 (AKA: STARBUCKS COFFEE) 6075 N LINCOLN AVE, CHICAGO 60659 Restaurant
June 24, 2020 Canvass License #1422751
7
Total Violations
4
Critical
2
Major
1
Minor

Inspection Summary

This restaurant was inspected by the Chicago Department of Public Health on June 24, 2020. The inspection type was "Canvass" and resulted in a Fail outcome.

This establishment is classified as Risk 2 (Medium), which determines the inspection frequency and focus areas.

The inspector documented 7 violations during this inspection, including 4 critical violations that required immediate attention.

Violations Cited by Chicago Health Inspector

7
Violation #5
CRITICAL
PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS - Comments: OBSERVED CLEAN-UP OF VOMITING AND DIARRHEA PROCEDURE ON SITE BUT CLEAN-UP KIT ON PREMISES DURING INSPECTION OBSERVED TO BE BLOOD BORNE PATHOGEN CLEAN UP KIT WITH OUT PROPER SANITIZING SOLUTION AND NO MOP FOR VOMIT CLEAN UP . INSTRUCTED TO HAVE SAID PROCEDURE ALONG WITH REQUIRED EQUIPMENT FOR CLEAN-UP. PRIORITY FOUNDATION VIOLATION. NO CITATION ISSUED. 7-38-005
Vomit and diarrhea contain millions of viral particles. One incident can contaminate entire facility and cause outbreak affecting dozens.
Written procedures required for cleaning bodily fluid events to prevent disease transmission.
Written procedure must address: Isolating contaminated area; Removing and discarding affected food; Using proper PPE; Cleaning and sanitizing with appropriate concentration; Proper disposal of contaminated materials.
Violation #22
CRITICAL
PROPER COLD HOLDING TEMPERATURES - Comments: FOUND TCS FOOD AT IMPROPER TEMPERATURE: 3 HAM SANDWICHES 54 F,VEGGIE WRAPS 55 F ,6 HAM & CHEESE SANDWICHES 55 F,28 EGG BITES 54-55 F,MENTIONED PRODUCTS WERE STORED INSIDE THE REACH UNDER COOLER .FOOD DISCARDED AND DENATURED BY EMPLOYEE.PRIORITY VIOLATION:7-38-005,NO CITATION ISSUED.
Temperatures below 135°F allow bacteria to multiply, especially spore-formers that survive cooking.
Hot foods must be held at 135°F or above.
Maintain 135°F or above; Check temperatures regularly; Proper hot holding equipment; Cannot reheat in hot holding units.
Violation #33
MAJOR
PROPER COOLING METHODS USED; ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL - Comments: OBSERVED IMPROPER TEMPERATURE OF REACH UNDER REFRIGERATOR AT 60.9 F WITH TCS FOODS STORED INSIDE FOR SALE.A HELD FOR INSPECTION TAG HAS BEEN PLACED ON UNIT.ONCE REPAIRED,FAX OR EMAIL TO CDPH. MUST HAVE COLD HOLDING FOODS AT 41.0 F OR BELOW.(PRIORITY VIOLATION) 7-38-005 NO CITATION ISSUED
Dirty equipment harbors bacteria and attracts pests.
All equipment and utensils must be clean and properly maintained.
Equipment clean to sight and touch; Free of food debris and grease; Maintained in good repair; Stored properly when clean.
Violation #40
MINOR
PERSONAL CLEANLINESS - Comments: OBSERVED THAT EMPLOYEE WORE RINGS ON HANDS WHILE WORKING WITH EXPOSED FOOD.MUST REMOVE ALL JEWELRY EXCEPT PLAIN WEDDING BAND FROM HANDS WHILE WORKING WITH EXPOSED FOOD
Poor personal hygiene transfers contaminants to food.
Food handlers must maintain personal cleanliness.
Clean outer clothing; Hair restraints; Short, clean fingernails; No jewelry except plain ring; Clean hands and arms.
Violation #48
CRITICAL
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: FACILITY USES HIGH TEMPERATURE SANITIZING DISH MACHINE AND DOESN'T HAVE PROPER TEMPERATURE MEASURING IRREVERSIBLE REGISTERING TEMPERATURE INDICATOR OR THERMOMETER THAT SHALL BE PROVIDED AND READILY ACCESSIBLE FOR MEASURING THE UTENSIL SURFACE TEMPERATURE DURING HOT WATER SANITATION. PRIORITY FOUNDATION VIOLATION 7-38-005 NO CITATION ISSUED
Cannot verify sanitization without test strips, risking contaminated equipment.
Warewashing facilities must be properly equipped and supplied.
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: BACKFLOW PREVENTION DEVICES NOT LOCATED AT ICE MACHINE . MUST INSTALL SO BACKFLOW PREVENTION DEVICES OR AIR GAP BETWEEN THE WATER SUPPLY INLET AND THE UNIT SO IT MAY BE LOCATED TO BE SERVICED AND MAINTAINED.
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: BACKFLOW PREVENTION DEVICES NOT LOCATED AT ICE MACHINE . MUST INSTALL SO BACKFLOW PREVENTION DEVICES OR AIR GAP BETWEEN THE WATER SUPPLY INLET AND THE UNIT SO IT MAY BE LOCATED TO BE SERVICED AND MAINTAINED.
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection
Data sourced from Chicago Open Data Portal - Chicago Department of Public Health inspections