Violations Cited by Chicago Health Inspector
3
Violation #10
CRITICAL
Violation Details
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: OBSERVED THE FAUCETS IN THE GIRLS WASHROOM ON THE FIRST FLOOR DO NOT STAY ON THE REQUIRED MINIMUM TIME OF 15 SECONDS; INSTRUCTED TO ADJUST FAUCETS.
Why This Matters
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Food Code Requirement
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Specific Requirements
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
CDPH Food Code: Section 5-202.12, 6-301.11
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED THE FOLLOWING PLUMBING VIOLATIONS: 1ST FLOOR BOYS COLD WATER KNOB IN POOR REPAIR, 2ND FLOOR GIRLS RIGHT SINK COLD WATER WONT STOP RUNNING, 2ND FLOOR BOYS BOTH COLD WATER KNOBS IN POOR REPAIR, 3RD FLOOR GIRLS LEFT SINK FAUCET KNOB IN POOR REPAIR. DISCUSSED REPAIRS WITH ENGINEER.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED THE FOLLOWING PLUMBING VIOLATIONS: 1ST FLOOR BOYS COLD WATER KNOB IN POOR REPAIR, 2ND FLOOR GIRLS RIGHT SINK COLD WATER WONT STOP RUNNING, 2ND FLOOR BOYS BOTH COLD WATER KNOBS IN POOR REPAIR, 3RD FLOOR GIRLS LEFT SINK FAUCET KNOB IN POOR REPAIR. DISCUSSED REPAIRS WITH ENGINEER.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13