⚠️ Recent Failed Inspections ⚠️
PASS W/ CONDITIONS Risk 1 (High)

SALAM RESTAURANT Gets Conditional Pass on Health Inspection - Chicago Restaurant

SALAM RESTAURANT 4634-4636 N KEDZIE AVE, CHICAGO 60625 Restaurant
October 23, 2024 Canvass License #2002822
12
Total Violations
5
Critical
2
Major
5
Minor

Violations Cited by Chicago Health Inspector

12
Violation #16
CRITICAL
FOOD-CONTACT SURFACES: CLEANED & SANITIZED - Comments: OBSERVED THE LOW TEMPERATURE DISH WASHING MACHINE "IN-USE" AT THIS TIME OF INSPECTION FINAL SANITIZING RINSE AT "0" PPM CHLORINE CONCENTRATION IN REAR KITCHEN PREP/DISHWASHING AREA.INSTRUCTED MANAGER TO REPAIR AND MAINTAIN. A MECHANICAL DISHWASHING MACHINES SHOULD PROVIDE A FINAL SANITIZING RINSE OF EITHER 50 ? 100 PPM CHLORINE (FOR CHEMICAL SANITIZING MACHINE) OR 180F FINAL RINSE (FOR HOT WATER SANITIZING MACHINE). DISHMACHINE IS TAGGED "HELD FOR INSPECTION".INSTRUCTED NOT TO USE UNTIL REPAIRED (** SEE COMMENTS BELOW). PRIORITY VIOLATION 7-38-025,CITATION ISSUED.
Dirty equipment harbors and spreads pathogens, causing cross-contamination and illness.
All food contact surfaces must be properly cleaned and sanitized.
Wash, rinse, sanitize after each use; Clean between different raw foods; Every 4 hours for continuous use; When contaminated; Proper procedures and chemicals.
Violation #23
CRITICAL
PROPER DATE MARKING AND DISPOSITION - Comments: OBSERVED READY-TO-EAT, TCS FOODS HELD FOR MORE THAN 24 HOURS (SOUP,RICE,HUMMUS ETC) NOT DATE MARKED TO INDICATE THE DATE IN WHICH THE FOOD MUST BE CONSUMED OR DISCARDED.INSTRUCTED MANAGEMENT TO DATE MARK ALL READY-TO-EAT,TCS FOODS HELD MORE THAN 24 HOURS.PRIORITY FOUNDATION VIOLATION 7-38-005,CITATION ISSUED.
Inadequate reheating fails to kill bacteria that grew during storage.
Foods must be reheated to 165°F within 2 hours.
Reheat to 165°F within 2 hours; Use proper equipment (not hot holding units); Discard if not reaching temperature in time.
Violation #37
MAJOR
FOOD PROPERLY LABELED; ORIGINAL CONTAINER - Comments: OBSERVED BULK CONTAINERS IN REAR STORAGE RACK WITHOUT A LABEL.INSTRUCTED TO PROVIDE THE COMMON NAME ON ALL BULK CONTAINERS TO PROPERLY IDENTIFY ITEM (NAME (SALT, SUGAR, FLOUR ETC).
Missing allergen labeling can cause severe allergic reactions.
All food properly labeled with required information.
Common name; Ingredients; Allergen declarations; Date marking; Manufacturer info; Net quantity.
Violation #38
CRITICAL
INSECTS, RODENTS, & ANIMALS NOT PRESENT - Comments: OBSERVED GAP OPENING APPROX:1/2" AT BOTTOM OF REAR EXIT DOOR LOCATED AT REAR FOOD PREP AREA.INSTRUCTED TO MAKE DOOR TIGHT FITTING ALL ACROSS THE BOTTOM TO PREVENT PEST ENTRY AND MAINTAIN.
Pests spread numerous diseases through contamination.
No pests or animals allowed in facility.
No evidence of pests; No live animals except service animals; Effective pest control program.
Violation #47
MINOR
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: OBSERVED STAINED CUTTING BOARDS ON TOP OF THE PREP LINE COOLERS.INSTRUCTED TO RESURFACE OR REPLACE THE CUTTING BOARDS AND MAINTAIN.
Poor design creates areas that harbor bacteria.
All surfaces must be designed to be easily cleanable.
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
Violation #47
MINOR
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: OBSERVED CHIPPED PAINT AND RUST ON THE WIRE STORAGE RACKS IN THE WALK-IN COOLER. INSTRUCTED TO REMOVE CHIPPED PAINT AND RUST AND REPAINT OR REPLACE THE SHELVES.
Poor design creates areas that harbor bacteria.
All surfaces must be designed to be easily cleanable.
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
Violation #48
CRITICAL
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: OBSERVED A SMALL KNIFE PUNCTURE INSIDE THE SANITIZE COMPARTMENT OF THE 3-COMPARTMENT SINK.INSTRUCTED TO REPAIR SO THAT IT IS SMOOTH,EASILY CLEANABLE AND NO WATER LEAKS.
Cannot verify sanitization without test strips, risking contaminated equipment.
Warewashing facilities must be properly equipped and supplied.
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.
Violation #49
MINOR
NON-FOOD/FOOD CONTACT SURFACES CLEAN - Comments: INSTRUCTED TO DETAIL CLEAN AND MAINTAIN STORAGE RACKS WITH EXCESSIVE WHITE MOLD LIKE BUILD-UP INSIDE WALK-IN COOLER.
Accumulated soil attracts pests and harbors bacteria.
All surfaces must be kept clean.
Clean equipment interiors and exteriors; Walls, ceilings, floors clean; Remove grease and debris; Clean as often as necessary.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED WATER LEAK AT DRAIN PIPE UNDERNEATH THE HAND SINK AT FRONT FOOD PREP AREA.INSTRUCTED TO REPAIR PLUMBING LEAK AND MAINTAIN.
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
Violation #53
MAJOR
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED - Comments: OBSERVED NO COVERED WASTE RECEPTACLE PROVIDED IN THE UNISEX WASHROOM. MUST PROVIDE AND MAINTAIN.
Inadequate facilities lead to poor hygiene and contamination.
Toilet rooms must be properly equipped and maintained.
Self-closing doors; Toilet paper; Covered waste receptacles; Handwashing supplies; Cleaned regularly; Proper ventilation.
Violation #56
MINOR
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: OBSERVED BURNT-OUT LIGHT BULB FOR LIGHT FIXTURE OVER THE REAR DISHWASHING 3-COMPARTMENT SINK AREA.INSTRUCTED TO REPLACE BURNT-OUT LIGHT BULB AND MAINTAIN ADEQUATE LIGHTING AT ALL TIMES.
Poor ventilation causes condensation and grease buildup; inadequate lighting hides contamination.
Proper ventilation and lighting required throughout.
Ventilation prevents condensation; Adequate lighting for operations; Fixtures shielded; Hoods over cooking equipment.
Violation #56
MINOR
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: OBSERVED BURNT-OUT LIGHT BULB FOR LIGHT FIXTURE OVER THE REAR DISHWASHING 3-COMPARTMENT SINK AREA.INSTRUCTED TO REPLACE BURNT-OUT LIGHT BULB AND MAINTAIN ADEQUATE LIGHTING AT ALL TIMES.
Poor ventilation causes condensation and grease buildup; inadequate lighting hides contamination.
Proper ventilation and lighting required throughout.
Ventilation prevents condensation; Adequate lighting for operations; Fixtures shielded; Hoods over cooking equipment.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection
Data sourced from Chicago Open Data Portal - Chicago Department of Public Health inspections