FAIL
Risk 1 (High)
PARK MANOR Fails Health Inspection - Chicago School
October 18, 2018
Canvass
License #24841
11
Total Violations
9
Critical
1
Major
1
Minor
Violations Cited by Chicago Health Inspector
11
Violation #3
CRITICAL
Violation Details
MANAGEMENT, FOOD EMPLOYEE AND CONDITIONAL EMPLOYEE; KNOWLEDGE, RESPONSIBILITIES AND REPORTING - Comments: 2-102.14N OBSERVED NO EMPLOYEE HEALTH POLICY ON SITE. MUST PROVIDE PRIORITY FOUNDATION VIOLATION 7-38-012(A)(A) NO CITATION ISSUED.
Why This Matters
Ill food workers cause 70% of foodborne outbreaks. Proper reporting prevents transmission of Norovirus, Hepatitis A, Salmonella, and other serious diseases.
Food Code Requirement
All food employees must understand and follow health reporting requirements and food safety responsibilities.
Specific Requirements
Employees must: Report illness symptoms and exposures; Be excluded/restricted when ill; Understand their role in preventing foodborne illness; Follow proper hygiene practices; Have signed health policy on file.
CDPH Food Code: Section 2-201.11 - 2-201.13
Violation #5
CRITICAL
Violation Details
PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS - Comments: 2-501.11 OBSERVED NO VOMITOUS AND DIARRHEAL INCIDENT CLEAN UP POLICY IN PLACE AND KIT ON SITE. MUST PROVIDE. PRIORITY FOUNDATION VIOLATION. 7-38-005. NO CITATION ISSUED.
Why This Matters
Vomit and diarrhea contain millions of viral particles. One incident can contaminate entire facility and cause outbreak affecting dozens.
Food Code Requirement
Written procedures required for cleaning bodily fluid events to prevent disease transmission.
Specific Requirements
Written procedure must address: Isolating contaminated area; Removing and discarding affected food; Using proper PPE; Cleaning and sanitizing with appropriate concentration; Proper disposal of contaminated materials.
CDPH Food Code: Section 2-501.11
Violation #10
CRITICAL
Violation Details
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: 5-202.12 OBSERVED HAND SINKS THROUGHT OUT FACILITY , GRILS, WOMEN, BOYS AND UNISEX IN DISREPAIR 1ST, 2ND, 3RD FLOORS, FAUCET NOT PROVIDING A FLOW OF WATER FOR AT LEAST 15 SECONDS WITHOUT THE NEED TO REACTIVATE THE FAUCET. MUST REPAIR ALL HANDSINK IN DISREPAIR AND NOT FLOWING FOR 15 SECONDS AND MAINTAIN.
Why This Matters
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Food Code Requirement
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Specific Requirements
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
CDPH Food Code: Section 5-202.12, 6-301.11
Violation #10
CRITICAL
Violation Details
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: 6-301.12 OBSERVED NO HAND DRYING PROVISION IN RESTROOMS THROUGHOUT FACILITY HAND DRYERS IN DISREPAIR IN RESTROOMS IN DISREPAIR. MUST OBTAIN, REPAIR AND MAINTAIN. PRIORITY FOUNDATION VIOLATION 7-38-030(C) NO CITATION ISSUED
Why This Matters
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Food Code Requirement
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Specific Requirements
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
CDPH Food Code: Section 5-202.12, 6-301.11
Violation #10
CRITICAL
Violation Details
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: OBSERVED HAND SINK IN FOOD PREP AREA NOT MEETING TEMPERATURE REQUIREMENTS,HOT WATER AT 94 DEGREES F. MUST REPAIR AND MAINTAIN. PRIORITY FOUNDATION VIOLATION. NO CITATION ISSUED
Why This Matters
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Food Code Requirement
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Specific Requirements
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
CDPH Food Code: Section 5-202.12, 6-301.11
Violation #38
CRITICAL
Violation Details
INSECTS, RODENTS, & ANIMALS NOT PRESENT - Comments: 6-202.16 OBSERVED EXIT/ENRTY DOOR #2 NOT TIGHT FITTED ABOVE 1/4 INCH GAP AT BOTTOM. MUST REPAIR AND MAINTAIN.
Why This Matters
Pests spread numerous diseases through contamination.
Food Code Requirement
No pests or animals allowed in facility.
Specific Requirements
No evidence of pests; No live animals except service animals; Effective pest control program.
CDPH Food Code: Section 6-501.111
Violation #48
CRITICAL
Violation Details
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: 4-501.19 OBSERVED MANUAL EQUIPMENT NOT MEET STANDARD REQUIREMENTS; WAREWASHING EQUIPMENT WASH SOLUTION LESS THAN 110 DEGREES F. THREE COMPARTMENT SINK HOT WATER AT 94 DEGREES F FOR FAUCET (WASH BASIN). MUST REPAIR AND MAINTAIN PRIORITY FOUNDATION VIOLATION 7-38-025. NO CITATION ISSUED.
Why This Matters
Cannot verify sanitization without test strips, risking contaminated equipment.
Food Code Requirement
Warewashing facilities must be properly equipped and supplied.
Specific Requirements
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.
CDPH Food Code: Section 4-302.14
Violation #50
CRITICAL
Violation Details
HOT & COLD WATER AVAILABLE; ADEQUATE PRESSURE - Comments: OBSERVED NO HOT WATER IN FOOD PREP AREA, HOT WATER AT (94-101 DEGREES F) IN PREP KITCHEN AND THROUGHT OUT FACILITY. MUST OBTAIN AND MAINTAIN HOT WATER.
Why This Matters
Without proper water temperatures, cannot sanitize or clean properly.
Food Code Requirement
Adequate hot and cold running water required.
Specific Requirements
Hot water 120°F minimum at fixtures; Cold water available; Sufficient pressure; From approved source.
CDPH Food Code: Section 5-103.11
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: 5-205.15 OBSERVED 3 COMPARTMENT SINK (LEAKING)FAUCET IN DISREPAIR IN FOOD PREP AREA. MUST REPAIR AND MAINTAIN.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Violation #53
MAJOR
Violation Details
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED - Comments: OBSERVED TOILETS IN DISREPAIR THROUGHT OUT FACILITY. MUST REPAIR AND MAINTAIN. PRIORITY FOUNDATION VIOLATION.
Why This Matters
Inadequate facilities lead to poor hygiene and contamination.
Food Code Requirement
Toilet rooms must be properly equipped and maintained.
Specific Requirements
Self-closing doors; Toilet paper; Covered waste receptacles; Handwashing supplies; Cleaned regularly; Proper ventilation.
CDPH Food Code: Section 6-302.11
Violation #53
MAJOR
Violation Details
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED - Comments: OBSERVED TOILETS IN DISREPAIR THROUGHT OUT FACILITY. MUST REPAIR AND MAINTAIN. PRIORITY FOUNDATION VIOLATION.
Why This Matters
Inadequate facilities lead to poor hygiene and contamination.
Food Code Requirement
Toilet rooms must be properly equipped and maintained.
Specific Requirements
Self-closing doors; Toilet paper; Covered waste receptacles; Handwashing supplies; Cleaned regularly; Proper ventilation.
CDPH Food Code: Section 6-302.11
Health Department Information
Department
Chicago Department of Public Health (CDPH)
Division
Food Protection Program
Report Issues
Call 311 or File Online
More Information
CDPH Food Protection