PASS W/ CONDITIONS
Risk 1 (High)
North-Grand H.S. Gets Conditional Pass on Health Inspection - Chicago School
May 12, 2015
Canvass
License #46431
5
Total Violations
3
Critical
1
Major
1
Minor
Violations Cited by Chicago Health Inspector
5
Violation #8
CRITICAL
Violation Details
SANITIZING RINSE FOR EQUIPMENT AND UTENSILS: CLEAN, PROPER TEMPERATURE, CONCENTRATION, EXPOSURE TIME - Comments: OBSERVED EMPLOYEE WASHING A PERSONAL DRINKING CUP IN THE MAIN KITCHEN TWO COMPARTMENT PREP SINK. INSTRUCTED TO USE THE THREE COMPARTMENT SINK FOR ALL WASHING, RINSING, SANITIZING OF ALL DISHES. CRITICAL VIOLATION 7-38-030.
Why This Matters
Improper sanitization fails to kill pathogens, allowing contaminated equipment to spread illness throughout facility.
Food Code Requirement
Sanitizing solutions and rinse water must meet specific requirements for effectiveness.
Specific Requirements
Chemical sanitizers: Chlorine 50-100 ppm, Quaternary ammonium 200-400 ppm, Iodine 12.5-25 ppm; Hot water: 171°F for 30 seconds or 180°F at dish surface; Test strips required; Proper contact time.
CDPH Food Code: Section 4-501.114, 4-702.11
Violation #12
CRITICAL
Violation Details
HAND WASHING FACILITIES: WITH SOAP AND SANITARY HAND DRYING DEVICES, CONVENIENT AND ACCESSIBLE TO FOOD PREP AREA - Comments: NO PAPER TOWELS AT THE MAIN KITCHEN EXPOSED HAND SINK. NO SOAP AT THE SERVING LINE EXPOSED HAND SINK. MUST PROVIDE AT ALL TIMES. ENGINEER PROVIDED DURING THE INSPECTION. CRITICAL VIOLATION 7-38-030.
Why This Matters
Missing supplies prevent proper handwashing, forcing inadequate cleaning that spreads pathogens.
Food Code Requirement
All handwashing sinks must have soap and hand drying provisions.
Specific Requirements
Soap in dispensers at each sink; Paper towels in dispensers or air dryers; Supplies maintained during all hours; Waste receptacles if paper towels used.
CDPH Food Code: Section 6-301.11, 6-301.12
Violation #16
CRITICAL
Violation Details
FOOD PROTECTED DURING STORAGE, PREPARATION, DISPLAY, SERVICE AND TRANSPORTATION - Comments: OBSERVED RAW EGGS BEING STORED ON REFRIGERATOR SHELVING DIRECTLY ABOVE FRESH VEGETABLES IN THE CULINARY CLASS KITCHEN. INSTRUCTED TO STORE RAW EGGS ON BOTTOM SHELVING AND PROTECT FOODS AT ALL TIMES. MANAGER REMOVED EGGS. SERIOUS VIOLATION 7-38-005(A).
Why This Matters
Dirty equipment harbors and spreads pathogens, causing cross-contamination and illness.
Food Code Requirement
All food contact surfaces must be properly cleaned and sanitized.
Specific Requirements
Wash, rinse, sanitize after each use; Clean between different raw foods; Every 4 hours for continuous use; When contaminated; Proper procedures and chemicals.
CDPH Food Code: Section 4-601.11, 4-602.11
Violation #36
MINOR
Violation Details
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: INOPERABLE LIGHTING INSIDE THE WALK-IN FREEZER. MUST PROVIDE ADEQUATE LIGHTING.
Why This Matters
Inadequate lighting prevents detection of contamination and pests.
Food Code Requirement
Adequate protected lighting required in all areas.
Specific Requirements
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.
CDPH Food Code: Section 6-303.11
Violation #36
MINOR
Violation Details
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: INOPERABLE LIGHTING INSIDE THE WALK-IN FREEZER. MUST PROVIDE ADEQUATE LIGHTING.
Why This Matters
Inadequate lighting prevents detection of contamination and pests.
Food Code Requirement
Adequate protected lighting required in all areas.
Specific Requirements
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.
CDPH Food Code: Section 6-303.11
Health Department Information
Department
Chicago Department of Public Health (CDPH)
Division
Food Protection Program
Report Issues
Call 311 or File Online
More Information
CDPH Food Protection