⚠️ Recent Failed Inspections ⚠️
FAIL Risk 1 (High)

MIDDLE BROW Fails Health Inspection - Chicago Restaurant

MIDDLE BROW 2002 N MOZART ST, CHICAGO 60647 Restaurant
January 3, 2019 License License #2609018
5
Total Violations
2
Critical
1
Major
2
Minor

Inspection Summary

This restaurant was inspected by the Chicago Department of Public Health on January 3, 2019. The inspection type was "License" and resulted in a Fail outcome.

This establishment is classified as Risk 1 (High), which determines the inspection frequency and focus areas.

The inspector documented 5 violations during this inspection, including 2 critical violations that required immediate attention.

Violations Cited by Chicago Health Inspector

5
Violation #38
CRITICAL
INSECTS, RODENTS, & ANIMALS NOT PRESENT - Comments: OBSERVED AN APPX."1/2" GAP ALONG TOP OF BEER DELIVERY DOOR,ALONG BOTTOM OF MAN DELIVERY DOOR AND SIDES OF OVERHEAD GARAGE DOOR.MUST MAKE DOORS TIGHT FITTING.
Pests spread numerous diseases through contamination.
No pests or animals allowed in facility.
No evidence of pests; No live animals except service animals; Effective pest control program.
Violation #39
MAJOR
CONTAMINATION PREVENTED DURING FOOD PREPARATION, STORAGE & DISPLAY - Comments: OBSERVED NO SNEEZE GUARD AT FRONT PREP AREA/BAR SEATING AREA FOR CUSTOMERS.MUST PROVIDE AND MAOINTAIN.(PRIORITY FOUNDATION-NO CITATION ISSUED)
Contamination during preparation is a leading cause of foodborne illness.
Prevent contamination during all food handling.
Minimize bare hand contact; Prevent cross-contamination; Use clean equipment; Proper employee hygiene.
Violation #47
MINOR
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: MUST APPLY A SEALANT OR PAINT RAW WOOD TRIM ON EXTERIOR OF WALK IN COOLERS AND FENCED IN BEER BARREL AREA.
Poor design creates areas that harbor bacteria.
All surfaces must be designed to be easily cleanable.
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: MUST REPAIR OR REPLACE LEAKY PIPE AT REAR 3- COMPARTMENT SINK.
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: MUST REPAIR OR REPLACE LEAKY PIPE AT REAR 3- COMPARTMENT SINK.
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection
Data sourced from Chicago Open Data Portal - Chicago Department of Public Health inspections