⚠️ Recent Failed Inspections ⚠️
FAIL Risk 2 (Medium)

MCDONALDS RESTAURANT Fails Health Inspection - Chicago Restaurant

MCDONALDS RESTAURANT 3154 W FOSTER AVE, CHICAGO 60625 Restaurant
October 25, 2019 Complaint License #2384975
9
Total Violations
2
Critical
2
Major
5
Minor
1
Corrected On Site

Violations Cited by Chicago Health Inspector

9
Violation #16
CORRECTED CRITICAL
FOOD-CONTACT SURFACES: CLEANED & SANITIZED - Comments: OBSERVED BLACK SLIMY SUBSTANCES ON INTERIOR WATER COMPONENTS OF THE ICE MAKER,DRIPPING INTO ICE "ICE IS USED FOR HUMAN CONSUMPTION". MANAGEMENT WAS INSTRUCTED TO TURN OFF MACHINE, REMOVE ICE AND HAVE INTERIOR OF ICE MACHINE CLEANED AND SANITIZED AND MAINTAIN. PRIORITY FOUNDATION VIOLATION 7-38-005,CITATION ISSUED. MANAGEMENT CORRECTED ON SITE AT THIS TIME(COS).
Dirty equipment harbors and spreads pathogens, causing cross-contamination and illness.
All food contact surfaces must be properly cleaned and sanitized.
Wash, rinse, sanitize after each use; Clean between different raw foods; Every 4 hours for continuous use; When contaminated; Proper procedures and chemicals.
This violation was corrected during the inspection.
Violation #47
MINOR
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: INSTRUCTED TO REPLACE WORNED OUT CAULK ABOVE ALONG THE DISH WASHING 3 COMPARTMENT SINK AREA AND MAINTAIN TO SMOOTH,EASILY CLEANABLE SURFACE.
Poor design creates areas that harbor bacteria.
All surfaces must be designed to be easily cleanable.
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
Violation #51
CRITICAL
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: BACK FLOW PREVENTION DEVICE NOT LOCATED AT ICE MACHINE. MUST INSTALL SO BACK FLOW PREVENTION DEVICES MAY BE LOCATED TO BE SERVICED AND MAINTAINED.
Backflow can contaminate entire water supply with sewage or chemicals.
Plumbing must be properly installed with backflow prevention.
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
Violation #53
MAJOR
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED - Comments: A toilet room used by females shall be provided with a covered receptacle for sanitary napkins.
Inadequate facilities lead to poor hygiene and contamination.
Toilet rooms must be properly equipped and maintained.
Self-closing doors; Toilet paper; Covered waste receptacles; Handwashing supplies; Cleaned regularly; Proper ventilation.
Violation #54
MAJOR
GARBAGE & REFUSE PROPERLY DISPOSED; FACILITIES MAINTAINED - Comments: FOUND OUTSIDE GARBAGE DUMPSTERS NOT MAINTAINED OBSERVED DAMAGED LIDS 4-5 INCH HOLES AT CORNERS AND ON CENTER OF LID.INSTRUCTED TO REPAIR/REPLACE MENTIONED GARBAGE DUMPSTER LIDS TO PREVENT FOOD SOURCE FOR PESTS AND TO MAINTAIN. PRIORITY FOUNDATION VIOLATION 7-38-020(B),CITATION ISSUED.
Poor waste management attracts pests and creates contamination sources.
Refuse must be properly contained and removed.
Leak-proof, pest-proof containers; Tight-fitting lids; Clean storage areas; Frequent removal; Containers cleaned.
Violation #55
MINOR
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: INSTRUCTED TO DETAIL CLEAN AND ORGANIZE REAR EMPLOYEE CLOSET AREA AND REMOVE UNNECESSARY ARTICLES DUE TO POTENTIAL PEST HARBORAGE AND TO MAINTAIN.
Deteriorated facilities harbor pests and prevent proper cleaning.
Building must be maintained in good condition.
No holes in walls/ceilings; Doors and windows intact; Fixtures functional; No water damage; Surfaces intact.
Violation #55
MINOR
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: INSTRUCTED TO REPLACE WATER STAINED CEILING TILES AT REAR CUSTOMER DINING AREA NEAR THE WASH ROOMS AND TO MAINTAIN.
Deteriorated facilities harbor pests and prevent proper cleaning.
Building must be maintained in good condition.
No holes in walls/ceilings; Doors and windows intact; Fixtures functional; No water damage; Surfaces intact.
Violation #55
MINOR
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: INSTRUCTED TO SEAL NOTICEABLE OPENINGS ON CEILING AROUND ELECTRICAL PIPES LOCATED IN REAR HOT WATER TANK AREA AND TO MAINTAIN.
Deteriorated facilities harbor pests and prevent proper cleaning.
Building must be maintained in good condition.
No holes in walls/ceilings; Doors and windows intact; Fixtures functional; No water damage; Surfaces intact.
Violation #55
MINOR
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: INSTRUCTED TO SEAL NOTICEABLE OPENINGS ON CEILING AROUND ELECTRICAL PIPES LOCATED IN REAR HOT WATER TANK AREA AND TO MAINTAIN.
Deteriorated facilities harbor pests and prevent proper cleaning.
Building must be maintained in good condition.
No holes in walls/ceilings; Doors and windows intact; Fixtures functional; No water damage; Surfaces intact.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection
Data sourced from Chicago Open Data Portal - Chicago Department of Public Health inspections