PASS
Risk 1 (High)
JERK YARD Passes Health Inspection - Chicago Restaurant
March 5, 2025
Canvass
License #2966394
4
Total Violations
1
Critical
3
Minor
Violations Cited by Chicago Health Inspector
4
Violation #49
MINOR
Violation Details
NON-FOOD/FOOD CONTACT SURFACES CLEAN - Comments: MUST CLEAN THE INTERIOR OF THE WALK IN COOLERS(SHELVING,FLOORS AND WALL) TO REMOVE SPILLS AND DEBRIS.
Why This Matters
Accumulated soil attracts pests and harbors bacteria.
Food Code Requirement
All surfaces must be kept clean.
Specific Requirements
Clean equipment interiors and exteriors; Walls, ceilings, floors clean; Remove grease and debris; Clean as often as necessary.
CDPH Food Code: Section 4-601.11, 4-602.13
Violation #49
MINOR
Violation Details
NON-FOOD/FOOD CONTACT SURFACES CLEAN - Comments: MUST CLEAN AND MAINTAIN THE EXTERIOR OF THE COOKING EQUIPMENT.
Why This Matters
Accumulated soil attracts pests and harbors bacteria.
Food Code Requirement
All surfaces must be kept clean.
Specific Requirements
Clean equipment interiors and exteriors; Walls, ceilings, floors clean; Remove grease and debris; Clean as often as necessary.
CDPH Food Code: Section 4-601.11, 4-602.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED A LEAKY PIPE UNDERNEATH THE FRONT HAND SINK AND A LEAK AT THE FAUCET AT THE 3 COMP SINK. MUST REPAIR AND MAINTAIN.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED A LEAKY PIPE UNDERNEATH THE FRONT HAND SINK AND A LEAK AT THE FAUCET AT THE 3 COMP SINK. MUST REPAIR AND MAINTAIN.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Health Department Information
Department
Chicago Department of Public Health (CDPH)
Division
Food Protection Program
Report Issues
Call 311 or File Online
More Information
CDPH Food Protection