⚠️ Recent Failed Inspections ⚠️
FAIL Risk 1 (High)

HARRY CARAY'S TAVERN NAVY PIER Fails Health Inspection - Chicago Restaurant

HARRY CARAY'S TAVERN NAVY PIER 700 E GRAND AVE, CHICAGO 60611 Restaurant
May 12, 2011 Canvass License #1998221
6
Total Violations
1
Critical
3
Major
2
Minor

Violations Cited by Chicago Health Inspector

6
Violation #18
CRITICAL
NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS - Comments: INADEQUATE PEST CONTORL (7-38-020). NOTED AT LEAST 16-SMALL/FRUIT FLIES ON WALL & CEILING AROUND WAIT STAFF AREA BY THE BAR; 4-ON SODA SYRUP BOXES BY MOP SINK & 4-ON EXTERIOR DOOR OF BEER COOLER. INSTRUCTED TO CONTACT P.C.O., ELIMINATE PESTS & CLEAN ALL AFFECTED AREAS. All necessary control measures shall be used to effectively minimize or eliminate the presence of rodents, roaches, and other vermin and insects on the premises of all food establishments, in food-transporting vehicles, and in vending machines.
Unprotected openings allow pest entry, leading to contamination of food and surfaces.
Building openings must be protected against pest entry.
Doors tight-fitting and self-closing; Windows screened; Openings sealed; Pest control log maintained; Regular monitoring; Professional service when needed.
Violation #24
MAJOR
DISH WASHING FACILITIES: PROPERLY DESIGNED, CONSTRUCTED, MAINTAINED, INSTALLED, LOCATED AND OPERATED - Comments: INADEQUATE PLUMBING (7-38-030). FOUND BOTTOM PIPE AT LEFT SIDE OF 3-COMP SINK (IN DISHROOM) LEAKING PROFUSELY ONTO THE FLOOR. INSTRUCTED TO FIX & MAINTAIN, TO KEEP FLOORS DRY. All dishwashing machines must be of a type that complies with all requirements of the plumbing section of the Municipal Code of Chicago and Rules and Regulation of the Board of Health.
Inadequate facilities prevent proper cleaning and sanitization of equipment.
Warewashing facilities must meet design and operational requirements.
3-compartment sink with drainboards; Mechanical dishwasher with proper temperatures; Test strips; Thermometers; Adequate size.
Violation #32
MAJOR
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED - Comments: CUTTING BOARDS WITH DEEP GROOVES MUST BE REPLACED. All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair.
Unapproved processes may lack critical safety controls.
Variance required before conducting specialized food processes.
Submit application to CDPH; Include HACCP plan; Await approval before starting; Maintain all required records.
Violation #34
MINOR
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED - Comments: FLOOR DRAINS IN BAR AREA & AT REAR OF KITCHEN (BY SODA SYRUP ROOM) NEED CLEANING-DUE TO FOOD DEBRIS/DIRT. ALL SUPPLIES/STOCK MUST BE ELEVATED OFF THE FLOOR (MEZZANINE LEVEL). The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair.
Damaged floors harbor bacteria and create safety hazards.
Floors must be smooth, cleanable, and maintained.
Smooth, non-porous in food areas; Properly sloped to drains; Coving at wall junctures; Kept clean; Good repair.
Violation #36
MINOR
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: MISSING LIGHT SHIELDS IN WALK-IN COOLER & AT DISHROOM, MUST BE REPLACED. Shielding to protect against broken glass falling into food shall be provided for all artificial lighting sources in preparation, service, and display facilities.
Inadequate lighting prevents detection of contamination and pests.
Adequate protected lighting required in all areas.
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.
Violation #36
MINOR
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: MISSING LIGHT SHIELDS IN WALK-IN COOLER & AT DISHROOM, MUST BE REPLACED. Shielding to protect against broken glass falling into food shall be provided for all artificial lighting sources in preparation, service, and display facilities.
Inadequate lighting prevents detection of contamination and pests.
Adequate protected lighting required in all areas.
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.

Health Department Information

Department Chicago Department of Public Health (CDPH)
Division Food Protection Program
Report Issues Call 311 or File Online
More Information CDPH Food Protection
Data sourced from Chicago Open Data Portal - Chicago Department of Public Health inspections