FAIL
Risk 1 (High)
ELLY'S PANCAKE HOUSE Fails Health Inspection - Chicago Restaurant
December 14, 2020
Canvass Re-Inspection
License #2314428
5
Total Violations
1
Critical
4
Minor
Violations Cited by Chicago Health Inspector
5
Violation #10
CRITICAL
Violation Details
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: 5-204.11 OBSERVED NO ADDITIONAL EXPOSED HAND WASHING SINK AT THE FOOD PREP LINE THAT IS CONVENIENT TO USE. MANAGEMENT INSTRUCTED TO INSTALL AN ADDITIONAL EXPOSED HAND WASHING SINK ON THE OPPOSITE END OF THE FOOD PREP LINE SUPPLIED WITH HOT AND COLD RUNNING WATER AND SOAP AND PAPER TOWELS. PRIORITY FOUNDATION 7-38-030(C). NO CITATION ISSUED.
Why This Matters
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Food Code Requirement
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Specific Requirements
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
CDPH Food Code: Section 5-202.12, 6-301.11
Violation #47
MINOR
Violation Details
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: 4-101.19 OBSERVED EXPOSED INSULATION ON THE INSIDE OF THE DOOR OF THE 1 DOOR PREP COOLER AT THE END OF THE PREP LINE. MANAGEMENT INSTRUCTED TO COVER THE INTERIOR OF THE DOOR WITH A SMOOTH AND EASILY CLEANABLE SURFACE.
Why This Matters
Poor design creates areas that harbor bacteria.
Food Code Requirement
All surfaces must be designed to be easily cleanable.
Specific Requirements
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
CDPH Food Code: Section 4-101.11
Violation #55
MINOR
Violation Details
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN - Comments: 6-501.11 OBSERVED SECTIONS OF THE CEILING IN DISREPAIR AT THE FRONT SERVICE PREP AREA IN FRONT OF THE COOK'S LINE. MANAGEMENT INSTRUCTED TO REPAIR THE CEILING DRYWALL IN THIS AREA.
Why This Matters
Deteriorated facilities harbor pests and prevent proper cleaning.
Food Code Requirement
Building must be maintained in good condition.
Specific Requirements
No holes in walls/ceilings; Doors and windows intact; Fixtures functional; No water damage; Surfaces intact.
CDPH Food Code: Section 6-501.11
Violation #56
MINOR
Violation Details
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: 6-202.11 OBSERVED LIGHT SHIELDS MISSING FROM THE DISHWASHING ROOM AND THE REAR PREP AREA NEXT TO THE ICE MACHINE. MANAGEMENT INSTRUCTED TO REPLACE ALL MISSING LIGHT SHIELDS.
Why This Matters
Poor ventilation causes condensation and grease buildup; inadequate lighting hides contamination.
Food Code Requirement
Proper ventilation and lighting required throughout.
Specific Requirements
Ventilation prevents condensation; Adequate lighting for operations; Fixtures shielded; Hoods over cooking equipment.
CDPH Food Code: Section 6-303.11, 6-304.11
Violation #56
MINOR
Violation Details
ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED - Comments: 6-202.11 OBSERVED LIGHT SHIELDS MISSING FROM THE DISHWASHING ROOM AND THE REAR PREP AREA NEXT TO THE ICE MACHINE. MANAGEMENT INSTRUCTED TO REPLACE ALL MISSING LIGHT SHIELDS.
Why This Matters
Poor ventilation causes condensation and grease buildup; inadequate lighting hides contamination.
Food Code Requirement
Proper ventilation and lighting required throughout.
Specific Requirements
Ventilation prevents condensation; Adequate lighting for operations; Fixtures shielded; Hoods over cooking equipment.
CDPH Food Code: Section 6-303.11, 6-304.11