⚠️ Recent Failed Inspections ⚠️
FAIL Risk 1 (High)

ELEPHANT & CASTLE PUB & RESTAURANT Fails Health Inspection - Chicago Restaurant

ELEPHANT & CASTLE PUB & RESTAURANT 111 W ADAMS ST, CHICAGO 60603 Restaurant
July 12, 2016 Complaint License #2142609
6
Total Violations
3
Critical
1
Major
2
Minor

Violations Cited by Chicago Health Inspector

6
Violation #8
CRITICAL
SANITIZING RINSE FOR EQUIPMENT AND UTENSILS: CLEAN, PROPER TEMPERATURE, CONCENTRATION, EXPOSURE TIME - Comments: INADEQUATE UTENSILS SANITATION, FOUND LOW TEMP DISH MACHINE WITH NO SANITIZER TRACES ON TEST STRIPS. INSTRUCTED MGR TO PROVIDE PROPER SANITIZER CONCENTRATION AT FINAL RINSE. MACHINE IS TAGGED NOT ALLOWED TO USE, MUST CONTACT THE OFFICE OF CDPH FOR TAG REMOVAL REQUEST. CRITICAL CITATION ISSUED 7-38-030.
Improper sanitization fails to kill pathogens, allowing contaminated equipment to spread illness throughout facility.
Sanitizing solutions and rinse water must meet specific requirements for effectiveness.
Chemical sanitizers: Chlorine 50-100 ppm, Quaternary ammonium 200-400 ppm, Iodine 12.5-25 ppm; Hot water: 171°F for 30 seconds or 180°F at dish surface; Test strips required; Proper contact time.
Violation #18
CRITICAL
NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS - Comments: INADEQUATE INSECTS CONTROL, FOUND 4 LIVE COCKROACHES CRAWLING ON KITCHEN'S WALL. INSTRUCTED TO ELIMINATE INSECTS ACTIVITY IN ALL AFFECTED AREAS. PEAST CONTROL SERVICE RECOMMENDED. SERIOUS CITATION ISSUED. 7-38-020.
Unprotected openings allow pest entry, leading to contamination of food and surfaces.
Building openings must be protected against pest entry.
Doors tight-fitting and self-closing; Windows screened; Openings sealed; Pest control log maintained; Regular monitoring; Professional service when needed.
Violation #32
MAJOR
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED - Comments: MISSING INSULATION IN BASEMENTS WALK-IN COOLER COOLING LINES. INSTRUCTED TO REPLACE.
Unapproved processes may lack critical safety controls.
Variance required before conducting specialized food processes.
Submit application to CDPH; Include HACCP plan; Await approval before starting; Maintain all required records.
Violation #35
MINOR
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS - Comments: LEAKY CEILING ABOVE 3-COMP SINK. INSTRUCTED TO REPAIR.
Damaged surfaces cannot be properly cleaned and may harbor pests.
Walls and ceilings must be smooth, cleanable, and in good repair.
Smooth, washable surfaces in food areas; Light colored; No holes or cracks; Clean and maintained.
Violation #36
MINOR
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: CRACKED LIGHT SHIELD ON LIGHT FIXTURE ABOVE 3-COMP SINK.
Inadequate lighting prevents detection of contamination and pests.
Adequate protected lighting required in all areas.
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.
Violation #36
MINOR
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED - Comments: CRACKED LIGHT SHIELD ON LIGHT FIXTURE ABOVE 3-COMP SINK.
Inadequate lighting prevents detection of contamination and pests.
Adequate protected lighting required in all areas.
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.