Violation #47
MINOR
Violation Details
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: FOUND HEAVY RUST BUILD UP ON THE SHELVES INSIDE THE 2-DOOR PREP COOLER. MANAGEMENT INSTRUCTED TO REPAINT OR REPLACE THE RUSTED WIRE SHELVES AND MAINTAIN.
Why This Matters
Poor design creates areas that harbor bacteria.
Food Code Requirement
All surfaces must be designed to be easily cleanable.
Specific Requirements
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
CDPH Food Code: Section 4-101.11
Violation #47
MINOR
Violation Details
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED - Comments: NOTED FROZEN FISH STORED DIRECTLY INSIDE GROCERY BAGS IN THE CHEST FREEZER ON THE COOKS LINE. INSTRUCTED MANAGEMENT TO PROPERLY STORE ALL FOOD INSIDE APPROVED FOOD GRADE CONTAINERS.
Why This Matters
Poor design creates areas that harbor bacteria.
Food Code Requirement
All surfaces must be designed to be easily cleanable.
Specific Requirements
Smooth, non-porous surfaces; Free of cracks and crevices; Easily disassembled; Accessible for cleaning.
CDPH Food Code: Section 4-101.11
Violation #49
MINOR
Violation Details
NON-FOOD/FOOD CONTACT SURFACES CLEAN - Comments: FOUND HEAVY ICE BUILD UP INSIDE THE LEFT CHEST FREEZER LOCATED IN THE BASEMENT. INSTRUCTED MANAGEMENT TO REMOVE ICE, CLEAN, AND MAINTAIN.
Why This Matters
Accumulated soil attracts pests and harbors bacteria.
Food Code Requirement
All surfaces must be kept clean.
Specific Requirements
Clean equipment interiors and exteriors; Walls, ceilings, floors clean; Remove grease and debris; Clean as often as necessary.
CDPH Food Code: Section 4-601.11, 4-602.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: NOTED A LEAK COMING FROM THE LEFT FAUCET AND FAUCET BASE ON THE DISH AREA THREE COMPARTMENT SINK. INSTRUCTED MANAGEMENT TO REPAIR.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: FOUND PLASTIC BEING USED TO PLUG THE DRAINS AT THE BAR THREE COMPARTMENT SINK. MUST REMOVE PLASTIC AND PROVIDE WORKING DRAIN PLUGS.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: FOUND PLASTIC BEING USED TO PLUG THE DRAINS AT THE BAR THREE COMPARTMENT SINK. MUST REMOVE PLASTIC AND PROVIDE WORKING DRAIN PLUGS.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13