FAIL
Risk 2 (Medium)
EIFFEL WAFFLE 4, INC. Fails Health Inspection - Chicago Restaurant
August 2, 2024
Complaint
License #2891364
12
Total Violations
9
Critical
1
Major
2
Minor
Violations Cited by Chicago Health Inspector
12
Violation #2
CRITICAL
Violation Details
CITY OF CHICAGO FOOD SERVICE SANITATION CERTIFICATE - Comments: OBSERVED NO CERTIFIED FOOD MANAGER ON SITE WHILE TCS FOODS ARE PREPARED AND SERVED. INSTRUCTED PERSON IN CHARGE TO ENSURE CERTIFIED FOOD MANAGER IS ON SITE AT ALL TIMES. PRIORITY FOUNDATION VIOLATION 7-38-012 CITATION ISSUED.
Why This Matters
Lack of certification indicates potential gaps in food safety knowledge, increasing risk of improper food handling and foodborne illness.
Food Code Requirement
Valid City of Chicago Food Service Sanitation Certificate required and must be posted.
Specific Requirements
Certificate must be: Current and valid; Posted conspicuously in public view; Held by person in charge during all operating hours; Renewed before expiration date.
CDPH Food Code: Section 2-102.11
Violation #3
CRITICAL
Violation Details
MANAGEMENT, FOOD EMPLOYEE AND CONDITIONAL EMPLOYEE; KNOWLEDGE, RESPONSIBILITIES AND REPORTING - Comments: OBSERVED NO EMPLOYEE HEALTH POLICY ON SITE. INSTRUCTED THE PERSON IN CHARGE TO PROVIDE EMPLOYEE HEALTH POLICY. PRIORITY FOUNDATION VIOLATION 7-38-010 CITATION ISSUED.
Why This Matters
Ill food workers cause 70% of foodborne outbreaks. Proper reporting prevents transmission of Norovirus, Hepatitis A, Salmonella, and other serious diseases.
Food Code Requirement
All food employees must understand and follow health reporting requirements and food safety responsibilities.
Specific Requirements
Employees must: Report illness symptoms and exposures; Be excluded/restricted when ill; Understand their role in preventing foodborne illness; Follow proper hygiene practices; Have signed health policy on file.
CDPH Food Code: Section 2-201.11 - 2-201.13
Violation #5
CRITICAL
Violation Details
PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS - Comments: OBSERVED NO BODILY FLUID CLEAN-UP KIT ON SITE. INSTRUCTED THE PERSON IN CHARGE TO PROVIDE A BODILY FLUID CLEAN-UP KIT. PRIORITY FOUNDATION VIOLATION 7-38-005 CITATION ISSUED.
Why This Matters
Vomit and diarrhea contain millions of viral particles. One incident can contaminate entire facility and cause outbreak affecting dozens.
Food Code Requirement
Written procedures required for cleaning bodily fluid events to prevent disease transmission.
Specific Requirements
Written procedure must address: Isolating contaminated area; Removing and discarding affected food; Using proper PPE; Cleaning and sanitizing with appropriate concentration; Proper disposal of contaminated materials.
CDPH Food Code: Section 2-501.11
Violation #10
CRITICAL
Violation Details
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: OBSERVED 2 HAND WASHING SINKS INACCESSIBLE DUE TO BEING BLOCKED. OBSERVED 1 HAND WASHING SINK BLOCKED BY COOLER AND 1 HAND WASHING SINK BLOCKED BY BUCKETS AND BOTTLES STORED IN SAID HAND WASHING SINK. INSTRUCTED PERSON IN CHARGE TO ENSURE ALL HAND WASHING SINKS ARE EASILY ACCESSIBLE. PRIORITY FOUNDATION VIOLATION 7-38-030(C) CITATION ISSUED.
Why This Matters
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Food Code Requirement
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Specific Requirements
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
CDPH Food Code: Section 5-202.12, 6-301.11
Violation #10
CRITICAL
Violation Details
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE - Comments: OBSERVED 2 HAND WASHING SINKS WITH NO PAPER TOWELS. OBSERVED 1 HAND WASHING SINK IN TOILET ROOM WITH BROKEN HAND DRYER. INSTRUCTED PERSON IN CHARGE TO ENSURE HAND DRY PROVISIONS ARE PROVIDED FOR ALL HAND WASHING SINKS. PAPER TOWELS PLACED AT HAND WASHING SINKS. PRIORITY FOUNDATION VIOLATION 7-38-030(C) CITATION CONSOLIDATED WITH PREVIOUS VIOLATION
Why This Matters
Blocked or unsupplied sinks force employees to skip handwashing, spreading fecal bacteria and viruses to food.
Food Code Requirement
Handwashing sinks must be accessible, properly supplied, and used only for handwashing.
Specific Requirements
Each sink needs: Warm water (100°F minimum); Soap in dispensers; Paper towels or air dryers; Waste receptacles; Signage; Clear access; Used only for handwashing.
CDPH Food Code: Section 5-202.12, 6-301.11
Violation #22
CRITICAL
Violation Details
PROPER COLD HOLDING TEMPERATURES - Comments: OBSERVED TCS FOODS STORED AT INADEQUATE TEMPERATURES RANGING FROM 49-52 F. INSTRUCTED THE PERSON IN CHARGE TO ENSURE ALL COLD FOOD IS HELD AT 41 F AND BELOW. THE PERSON IN CHARGE DISCARDED 7 GALLONS OF MILK AND 1 GALLON OF LIQUID EGG WHITES ($50). PRIORITY VIOLATION 7-38-005 CITATION ISSUED.
Why This Matters
Temperatures below 135°F allow bacteria to multiply, especially spore-formers that survive cooking.
Food Code Requirement
Hot foods must be held at 135°F or above.
Specific Requirements
Maintain 135°F or above; Check temperatures regularly; Proper hot holding equipment; Cannot reheat in hot holding units.
CDPH Food Code: Section 3-501.16(A)(1)
Violation #33
MAJOR
Violation Details
PROPER COOLING METHODS USED; ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL - Comments: OBSERVED 2-DOOR COOLER UNIT WITH AN INADEQUATE AMBIENT AIR TEMPERATURE OF 48 F. INSTRUCTED PERSON IN CHARGE TO ENSURE ALL COLD HOLDING UNITS HAVE AN AMBIENT AIR TEMPERATURE OF 41 F AND BELOW. COOLER TAGGED. PRIORITY VIOLATION 7-38-005 CITATION ISSUED
Why This Matters
Dirty equipment harbors bacteria and attracts pests.
Food Code Requirement
All equipment and utensils must be clean and properly maintained.
Specific Requirements
Equipment clean to sight and touch; Free of food debris and grease; Maintained in good repair; Stored properly when clean.
CDPH Food Code: Section 4-601.11
Violation #36
MINOR
Violation Details
THERMOMETERS PROVIDED & ACCURATE - Comments: OBSERVED NO METAL STEM FOOD THERMOMETER ON SITE FOR TAKING TEMPERATURES OF TCS FOODS. INSTRUCTED PERSON IN CHARGE TO PROVIDE METAL STEM FOOD THERMOMETER APPROPRIATE FOR OPERATIONS. PRIORITY FOUNDATION VIOLATION 7-38-005 CITATION ISSUED.
Why This Matters
Inadequate lighting prevents detection of contamination and pests.
Food Code Requirement
Adequate protected lighting required in all areas.
Specific Requirements
50 foot-candles at prep surfaces; 20 foot-candles at 30 inches in storage; Shielded bulbs over exposed food; Clean fixtures.
CDPH Food Code: Section 6-303.11
Violation #38
CRITICAL
Violation Details
INSECTS, RODENTS, & ANIMALS NOT PRESENT - Comments: OBSERVED MORE THAN 20 SMALL FLIES THROUGHOUT THE FACILITY, INCLUDING IN THE DISH AREA, NEAR THE PREP AREA, AND IN THE TOILET ROOM. INSTRUCTED MANAGER TO SERVICE ALL AREAS AFFECTED BY PESTS. PRIORITY FOUNDATION VIOLATION 7-38-020(A) CITATION ISSUED
Why This Matters
Pests spread numerous diseases through contamination.
Food Code Requirement
No pests or animals allowed in facility.
Specific Requirements
No evidence of pests; No live animals except service animals; Effective pest control program.
CDPH Food Code: Section 6-501.111
Violation #48
CRITICAL
Violation Details
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS - Comments: OBSERVED NO TEST STRIPS ON SITE FOR MEASURING SANITIZER CONCENTRATION. INSTRUCTED PERSON IN CHARGE TO PROVIDE TEST STRIPS. PRIORITY FOUNDATION VIOLATION 7-38-005 CITATION ISSUED.
Why This Matters
Cannot verify sanitization without test strips, risking contaminated equipment.
Food Code Requirement
Warewashing facilities must be properly equipped and supplied.
Specific Requirements
3-compartment sink or dishwasher; Test strips for sanitizer; Thermometers for water temperature; Adequate drainboards; Proper detergents.
CDPH Food Code: Section 4-302.14
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED 3-COMPARTMENT SINK WITH LEAK FROM FAUCET WHEN WATER IS RUN. INSTRUCTED MANAGER TO REPAIR.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Violation #51
CRITICAL
Violation Details
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES - Comments: OBSERVED 3-COMPARTMENT SINK WITH LEAK FROM FAUCET WHEN WATER IS RUN. INSTRUCTED MANAGER TO REPAIR.
Why This Matters
Backflow can contaminate entire water supply with sewage or chemicals.
Food Code Requirement
Plumbing must be properly installed with backflow prevention.
Specific Requirements
Air gaps at fixtures; Backflow preventers on connections; No cross-connections; Annual testing of devices; Proper drainage.
CDPH Food Code: Section 5-202.13
Health Department Information
Department
Chicago Department of Public Health (CDPH)
Division
Food Protection Program
Report Issues
Call 311 or File Online
More Information
CDPH Food Protection